Why Is Water Dripping from Your Indoor Unit?
Finding water dripping from your indoor air conditioner down your interior plasterwork, wallpaper, or bedroom floor requires prompt attention.
During normal summer cooling operation, your indoor evaporator coil acts like a cold beverage glass on a warm day, condensing moisture out of the air. This water is designed to collect in an internal drip tray and drain away safely to the outside of your property. When water overflows into the room, it points to a drainage or refrigeration fault.
Immediate Safety Precaution: Turn off the air conditioner at the remote control and isolate the unit at the electrical consumer unit to protect the internal fan motor and circuit board.
4 Common Causes of Condensate Leaks
Indoor water leaks typically stem from mechanical drainage restrictions, pump float failure, or evaporator icing faults:
1. Blocked Condensate Drain Line (Algae & Slime)
The most common cause of indoor leaks is a blocked drain pipe. The warm, damp environment inside condensate lines can encourage biological slime, mould, and airborne dust to collect, forming a blockage that backs up water into the indoor drip tray.
- Professional Fix: We clear the line with a vacuum purge, chemically flush the pipework, and place slow-dissolving biocidal tablets in the tray to prevent future buildup.
2. Failed Condensate Lift Pump
In installations without a continuous downhill gravity drain line (such as London apartments or units on internal walls), an electric condensate pump lifts water up into ceiling voids or soil stacks. If the pump’s reservoir float sticks, or the motor fails, water backs up quickly.
- Professional Fix: We test the reservoir float switch and replace failed pumps with quiet, reliable electronic peristaltic pumps.
3. Frozen Evaporator Coil Melting
If your system is low on R32 refrigerant or has severely blocked air filters, the indoor coil temperature drops below freezing, forming a block of ice. When the system is switched off, this ice melts rapidly, overwhelming the condensate tray.
- Professional Fix: We resolve the underlying cause by repairing refrigerant leaks or clearing airflow restrictions before checking the drainage system.
4. Cracked or Misaligned Internal Drain Pan
On older systems, the plastic condensate tray can become brittle, crack, or shift off level, allowing water to bypass the drain outlet entirely.
Our £85 Diagnostic Callout Fee Credit
Our experienced engineers carry replacement peristaltic pumps, flexible condensate hose, and biocide treatments to resolve water leaks on the first visit.
Our £85 diagnostic callout fee covers a complete on-site diagnosis. When you accept our repair quote, 100% of the £85 fee is credited against the final repair invoice.
Standard £85 diagnostic callout applies during regular business hours (100% credited toward approved repair). Emergency evening, weekend, and bank holiday appointments carry tiered out-of-hours rates confirmed prior to dispatch.